Содержание
Восстанавливаем конфиг с внешенй usb
<HUAWEI>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 14:48:26 $_checkpoint 1 dr-x - Jan 23 2020 10:45:28 $_install_mod 2 dr-x - Nov 03 2020 14:55:23 $_license 3 dr-x - Oct 11 2020 14:47:58 $_security_info 4 dr-x - Oct 11 2020 14:57:10 $_system 5 -rw- 128,772,300 Jan 04 2020 10:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 14:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 09:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 10:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 10:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 14:52:09 POST 11 -rw- 97 Nov 03 2020 14:52:12 collect_diag_info.bat 12 -rw- 17,086 Oct 11 2020 14:51:52 device.sys 13 drwx - Oct 11 2020 14:57:15 logfile 14 -rw- 2,598 Oct 11 2020 13:42:27 vrpcfg-test.zip 15 -rw- 907 Oct 11 2020 14:51:51 vrpcfg.zip 16 -rw- 5,914 Mar 04 2020 17:00:29 ztp_20200304165135.log 17 -rw- 13,961 Mar 04 2020 16:58:59 ztp_20200304165135.log.1 18 -rw- 824 Mar 04 2020 16:54:19 ztp_20200304165135.log.2 269,168 KB total (11,028 KB free) <HUAWEI>co <HUAWEI>compare <HUAWEI>configuration <HUAWEI>dir usb:/ Directory of usb:/ Idx Attr Size(Byte) Date Time FileName 0 -rw- 155,216 Apr 21 2020 20:25:28 AFUDOSU.SMC ... 13 -rw- 2,588 Oct 11 2020 14:27:10 bup-conf.zip 1,951,992 KB total (1,899,400 KB free) <HUAWEI>copy usb:/bup-conf.zip flash:/vrpcfg.zip Error: flash:/vrpcfg.zip is protected. <HUAWEI>copy usb:/bup-conf.zip flash:/vrpcfg-from-bup.zip Info: Are you sure to copy usb:/bup-conf.zip to flash:/vrpcfg-from-bup.zip? [Y/N]:y 100% complete Info: Copying file usb:/bup-conf.zip to flash:/vrpcfg-from-bup.zip...Done. <HUAWEI>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 14:58:00 $_checkpoint 1 dr-x - Jan 23 2020 10:45:28 $_install_mod 2 dr-x - Nov 03 2020 14:55:23 $_license 3 dr-x - Oct 11 2020 14:47:58 $_security_info 4 dr-x - Oct 11 2020 14:57:10 $_system 5 -rw- 128,772,300 Jan 04 2020 10:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 14:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 09:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 10:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 10:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 14:52:09 POST 11 -rw- 97 Nov 03 2020 14:52:12 collect_diag_info.bat 12 -rw- 17,086 Oct 11 2020 14:51:52 device.sys 13 drwx - Oct 11 2020 14:57:15 logfile 14 -rw- 2,588 Oct 11 2020 14:59:01 vrpcfg-from-bup.zip 15 -rw- 2,598 Oct 11 2020 13:42:27 vrpcfg-test.zip 16 -rw- 907 Oct 11 2020 14:51:51 vrpcfg.zip 17 -rw- 5,914 Mar 04 2020 17:00:29 ztp_20200304165135.log 18 -rw- 13,961 Mar 04 2020 16:58:59 ztp_20200304165135.log.1 19 -rw- 824 Mar 04 2020 16:54:19 ztp_20200304165135.log.2 269,168 KB total (11,020 KB free) <HUAWEI> <HUAWEI>dis startup MainBoard: Configured startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup saved-configuration file: flash:/vrpcfg.zip Next startup saved-configuration file: flash:/vrpcfg.zip Startup paf file: default Next startup paf file: default Startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT <HUAWEI>sta <HUAWEI>startup co <HUAWEI>startup sa <HUAWEI>startup saved-configuration fl <HUAWEI>startup saved-configuration flash:/v <HUAWEI>startup saved-configuration flash:/vrpcfg- <HUAWEI>startup saved-configuration flash:/vrpcfg-from-bup.zip Info: Operating, please wait for a moment......done. Info: Succeeded in setting the configuration for booting system. <HUAWEI>dis star <HUAWEI>dis startup MainBoard: Configured startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup saved-configuration file: flash:/vrpcfg.zip Next startup saved-configuration file: flash:/vrpcfg-from-bup.zip Startup paf file: default Next startup paf file: default Startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT <HUAWEI> <HUAWEI>reboot slot 1: Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup saved-configuration file: flash:/vrpcfg-from-bup.zip Next startup paf file: default Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Warning: The current configuration will be saved to the next startup saved-configuration file. Continue? [Y/N]:n Warning: The system will reboot. Continue? [Y/N]:y ************************************************************* * Copyright (C) <2020-2020> Huawei Technologies Co., Ltd. * ************************************************************* CloudEngine BIOS Version: 433 (Oct 11 2020 - 20:19:17) Board Name ..................................... CE6810-48S4Q-LI SDRAM Memory Initializing ...................... BEGIN SDRAM Memory Size .............................. 2 Gbytes SDRAM Memory Initializing ...................... DONE Press CTRL T for full memory test .............. skip Starting ... Press CTRL B to enter BIOS menu or CTRL E to boot DFX: 0 Boot Disk: flash Startup File: CE6810LI-V200R005C10SPC800.cc Try Times: 1 Check system software ........................................ DONE Check APPDB .................................................. DONE Set next bootfile ............................................ DONE Load system software ......................................... DONE Create file system ........................................... DONE Now starting VRP ........ Configured switch mode ....................................... AUTO-NEGOTIATION Current switch mode .......................................... STACK Press CTRL Y to modify the switch mode ....................... skip Initializing stack ........................................... DONE Stack member ID .............................................. 1 Stack domain ID .............................................. INVALID Stack priority ............................................... 100 Default MAC .................................................. 48-57-02-cc-ae-f0 Competing with other devices in the stack .................... DONE Stack role ................................................... MASTER User interface con0 is available Please Press ENTER. Password: Info: The max number of VTY users is 5, the number of current VTY users online is 0, and total number of terminal users online is 1. The current login time is 2020-10-11 18:07:05 03:00. <sw21> <sw21>dis startup MainBoard: Configured startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup saved-configuration file: flash:/vrpcfg-from-bup.zip Next startup saved-configuration file: flash:/vrpcfg-from-bup.zip Startup paf file: default Next startup paf file: default Startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT <slv-sw21>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 18:07:30 $_checkpoint 1 dr-x - Jan 23 2020 13:45:28 $_install_mod 2 dr-x - Nov 03 2020 17:55:23 $_license 3 dr-x - Oct 11 2020 18:07:01 $_security_info 4 dr-x - Oct 11 2020 18:07:01 $_system 5 -rw- 128,772,300 Jan 04 2020 13:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 17:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 12:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 13:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 13:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 17:52:09 POST 11 -rw- 97 Nov 03 2020 17:52:12 collect_diag_info.bat 12 -rw- 17,086 Oct 11 2020 18:01:33 device.sys 13 drwx - Oct 11 2020 17:57:15 logfile 14 -rw- 2,588 Oct 11 2020 17:59:01 vrpcfg-from-bup.zip 15 -rw- 2,598 Oct 11 2020 16:42:27 vrpcfg-test.zip 16 -rw- 907 Oct 11 2020 17:51:51 vrpcfg.zip 17 -rw- 5,914 Mar 04 2020 20:00:29 ztp_20200304165135.log 18 -rw- 13,961 Mar 04 2020 19:58:59 ztp_20200304165135.log.1 19 -rw- 824 Mar 04 2020 19:54:19 ztp_20200304165135.log.2 269,168 KB total (11,020 KB free) <slv-sw21>save Warning: The current configuration will be written to the device. Continue? [Y/N]:y Now saving the current configuration to the slot 1 . Info: Save the configuration successfully. <sw21>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 18:07:30 $_checkpoint 1 dr-x - Jan 23 2020 13:45:28 $_install_mod 2 dr-x - Nov 03 2020 17:55:23 $_license 3 dr-x - Oct 11 2020 18:07:01 $_security_info 4 dr-x - Oct 11 2020 18:07:01 $_system 5 -rw- 128,772,300 Jan 04 2020 13:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 17:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 12:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 13:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 13:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 17:52:09 POST 11 -rw- 97 Nov 03 2020 17:52:12 collect_diag_info.bat 12 -rw- 17,510 Oct 11 2020 18:08:08 device.sys 13 drwx - Oct 11 2020 17:57:15 logfile 14 -rw- 2,612 Oct 11 2020 18:08:08 vrpcfg-from-bup.zip 15 -rw- 2,598 Oct 11 2020 16:42:27 vrpcfg-test.zip 16 -rw- 907 Oct 11 2020 17:51:51 vrpcfg.zip 17 -rw- 5,914 Mar 04 2020 20:00:29 ztp_20200304165135.log 18 -rw- 13,961 Mar 04 2020 19:58:59 ztp_20200304165135.log.1 19 -rw- 824 Mar 04 2020 19:54:19 ztp_20200304165135.log.2 269,168 KB total (11,016 KB free) <sw21> <sw21>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 18:07:30 $_checkpoint 1 dr-x - Jan 23 2020 13:45:28 $_install_mod 2 dr-x - Nov 03 2020 17:55:23 $_license 3 dr-x - Oct 11 2020 18:07:01 $_security_info 4 dr-x - Oct 11 2020 18:07:01 $_system 5 -rw- 128,772,300 Jan 04 2020 13:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 17:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 12:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 13:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 13:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 17:52:09 POST 11 -rw- 97 Nov 03 2020 17:52:12 collect_diag_info.bat 12 -rw- 17,510 Oct 11 2020 18:18:10 device.sys 13 drwx - Oct 11 2020 17:57:15 logfile 14 -rw- 2,615 Oct 11 2020 18:18:10 vrpcfg-from-bup.zip 15 -rw- 2,598 Oct 11 2020 16:42:27 vrpcfg-test.zip 16 -rw- 907 Oct 11 2020 17:51:51 vrpcfg.zip 17 -rw- 5,914 Mar 04 2020 20:00:29 ztp_20200304165135.log 18 -rw- 13,961 Mar 04 2020 19:58:59 ztp_20200304165135.log.1 19 -rw- 824 Mar 04 2020 19:54:19 ztp_20200304165135.log.2 269,168 KB total (11,020 KB free) <sw21>save ? STRING<5-64> The name of specific file(*.cfg, *.zip, *.dat) flash: Device name logfile Save logfile usb: Device name <cr> <sw21>save vrpcfg.zip Warning: Are you sure to save the configuration to flash:/vrpcfg.zip? [Y/N]:y Warning: flash:/vrpcfg.zip exists,overwrite? [Y/N]:y Now saving the current configuration to the slot 1 Info: Save the configuration successfully. <sw21>dir flash: Directory of flash:/ Idx Attr Size(Byte) Date Time FileName 0 dr-x - Oct 11 2020 18:07:30 $_checkpoint 1 dr-x - Jan 23 2020 13:45:28 $_install_mod 2 dr-x - Nov 03 2020 17:55:23 $_license 3 dr-x - Oct 11 2020 18:07:01 $_security_info 4 dr-x - Oct 11 2020 18:07:01 $_system 5 -rw- 128,772,300 Jan 04 2020 13:21:49 CE6810LI-V200R002C50SPC800.cc 6 -rw- 1,339,283 Nov 03 2020 17:57:13 CE6810LI-V200R002SPH016.PAT 7 -rw- 4,206,539 Sep 19 2020 12:50:14 CE6810LI-V200R002SPH022.PAT 8 -rw- 135,653,156 Sep 19 2020 13:35:20 CE6810LI-V200R005C10SPC800.cc 9 -rw- 2,826,131 Sep 19 2020 13:36:08 CE6810LI-V200R005SPH008.PAT 10 drwx - Nov 03 2020 17:52:09 POST 11 -rw- 97 Nov 03 2020 17:52:12 collect_diag_info.bat 12 -rw- 17,510 Oct 11 2020 18:18:37 device.sys 13 drwx - Oct 11 2020 17:57:15 logfile 14 -rw- 2,615 Oct 11 2020 18:18:10 vrpcfg-from-bup.zip 15 -rw- 2,598 Oct 11 2020 16:42:27 vrpcfg-test.zip 16 -rw- 2,598 Oct 11 2020 18:18:37 vrpcfg.zip 17 -rw- 5,914 Mar 04 2020 20:00:29 ztp_20200304165135.log 18 -rw- 13,961 Mar 04 2020 19:58:59 ztp_20200304165135.log.1 19 -rw- 824 Mar 04 2020 19:54:19 ztp_20200304165135.log.2 269,168 KB total (11,020 KB free) <sw21>dis startup MainBoard: Configured startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup saved-configuration file: flash:/vrpcfg-from-bup.zip Next startup saved-configuration file: flash:/vrpcfg-from-bup.zip Startup paf file: default Next startup paf file: default Startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT <sw21>startup saved-configuration vrpcfg.zip Info: Operating, please wait for a moment......done. Info: Succeeded in setting the configuration for booting system. <sw21>dis startup MainBoard: Configured startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Startup saved-configuration file: flash:/vrpcfg-from-bup.zip Next startup saved-configuration file: flash:/vrpcfg.zip Startup paf file: default Next startup paf file: default Startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT <sw21>reboot slot 1: Next startup system software: flash:/CE6810LI-V200R005C10SPC800.cc Next startup saved-configuration file: flash:/vrpcfg.zip Next startup paf file: default Next startup patch package: flash:/CE6810LI-V200R005SPH008.PAT Warning: The system will reboot. Continue? [Y/N]:y
Настройка стекирования (istack)
После получения доступа к коммутаторам, при необходимости можно настроить стек. Для объединения нескольких коммутаторов в одно логическое устройство в Huawei CE используется технология iStack. Топология стека — кольцо, т.е. на каждом коммутаторе рекомендуется использовать минимум 2 порта. Количество портов зависит от желаемой скорости взаимодействия коммутаторов в стеке.
Желательно при стекировании задействовать аплинки, скорость которых обычно выше, чем у портов для подключения конечных устройств. Таким образом, можно получить большую пропускную способность при помощи меньшего количества портов. Также, для большинства моделей есть ограничения по использованию гигабитных портов для стекирования. Рекомендуется использовать минимум 10G порты.
Есть два варианта настройки, которые немного отличаются в последовательности шагов:
Предварительная настройка коммутаторов с последующим их физическим соединением.
Сначала установка и подключение коммутаторов между собой, потом их настройка для работы в стеке.
Последовательность действий для этих вариантов выглядит следующим образом:

Рассмотрим второй (более длительный) вариант настройки стека. Для этого нужно выполнить следующие действия:
Планируем работы с учётом вероятного простоя. Составляем последовательность действий.
Осуществляем монтаж и кабельное подключение коммутаторов.
Настраиваем базовые параметры стека для master-коммутатора:
[~HUAWEI] stack
3.1. Настраиваем нужные нам параметры
#
stack member 1 renumber X — где X — новый ID коммутатора в стэке. По умолчанию, ID = 1
и для master-коммутатора можно оставить ID по умолчанию.
#
stack member 1 priority 150 — указываем приоритет. Коммутатор с наибольшим
приоритетом будет назначен master-коммутатором стека. Значение приоритета
по умолчанию: 100.
#
stack member { member-id | all } domain <domain-id>— назначить Domain ID для стека.
По умолчанию, domain ID не задан.
#
Пример:
<HUAWEI> system-view
[~HUAWEI] sysname SwitchA
[HUAWEI] commit
[~SwitchA] stack
[~SwitchA-stack] stack member 1 priority 150
[SwitchA-stack] stack member 1 domain 10
[SwitchA-stack] quit
[SwitchA] commit
3.2 Настраиваем интерфейс порта стекирования (пример)
[~SwitchA] interface stack-port 1/1
[SwitchA-Stack-Port1/1] port member-group interface 10ge 1/0/1 to 1/0/4
Warning: After the configuration is complete,
1.The interface(s) (10GE1/0/1-1/0/4) will be converted to stack mode and be configured with the
port crc-statistics trigger error-down command if the configuration does not exist.
2.The interface(s) may go Error-Down (crc-statistics) because there is no shutdown configuration on the interfaces.Continue? [Y/N]: y
[SwitchA-Stack-Port1/1] commit
[~SwitchA-Stack-Port1/1] return
Далее, нужно сохранить конфигурацию и перезагрузить коммутатор:
4. Выключаем порты для стекирования на master-коммутаторе (пример)
[~SwitchA] interface stack-port 1/1
[*SwitchA-Stack-Port1/1] shutdown
[*SwitchA-Stack-Port1/1] commit
5. Настраиваем второй коммутатор в стэке по аналогии с первым:
<HUAWEI> system-view
[~HUAWEI] sysname SwitchB
[*HUAWEI] commit
[~SwitchB] stack
[~SwitchB-stack] stack member 1 priority 120
[*SwitchB-stack] stack member 1 domain 10
[*SwitchB-stack] stack member 1 renumber 2 inherit-config
Warning: The stack configuration of member ID 1 will be inherited to member ID 2
after the device resets. Continue? [Y/N]: y
[*SwitchB-stack] quit
[*SwitchB] commit
Настраиваем порты для стекирования. Обратите внимание, что несмотря на то, что была введена команда “stack member 1 renumber 2 inherit-config”, member-id в конфигурации используется со значением “1” для SwitchB.
Так происходит, потому что member-id коммутатора будет изменён только после перезагрузки и до неё коммутатор по-прежнему имеет member-id, равный 1. Параметр “inherit-config” как раз нужен для того, чтобы после перезагрузки коммутатора все настройки стека сохранились для member 2, которым и будет коммутатор, т.к. его member ID был изменён со значения 1 на значение 2.
[~SwitchB] interface stack-port 1/1[*SwitchB-Stack-Port1/1] port member-group interface 10ge 1/0/1 to 1/0/4Warning: After the configuration is complete,1.
The interface(s) (10GE1/0/1-1/0/4) will be converted to stackmode and be configured with the port crc-statistics trigger error-down command if the configuration doesnot exist.2.The interface(s) may go Error-Down (crc-statistics) because there is no shutdown configuration on theinterfaces.Continue? [Y/N]: y[*SwitchB-Stack-Port1/1] commit[~SwitchB-Stack-Port1/1] return
Перезагружаем SwitchB
<SwitchB> save
Warning: The current configuration will be written to the device. Continue? [Y/N]: y
<SwitchB> reboot
Warning: The system will reboot. Continue? [Y/N]: y
6. Включаем порты стекирования на master-коммутаторе. Важно успеть включить порты до завершения перезагрузки коммутатора B, т.к. если включить их после, коммутатор B снова уйдёт в перезагрузку.
[~SwitchA] interface stack-port 1/1[~SwitchA-Stack-Port1/1] undo shutdown[*SwitchA-Stack-Port1/1] commit[~SwitchA-Stack-Port1/1] return
7. Проверяем работу стека командой “display stack”
Пример вывода команды после правильной настройки
<SwitchA> display stack
———————————————————————————
MemberID Role MAC Priority DeviceType Description
———————————————————————————
1 Master 0004-9f31-d520 150 CE6850-48T4Q-EI
2 Standby 0004-9f62-1f40 120 CE6850-48T4Q-EI
———————————————————————————
indicates the device where the activated management interface resides.
8. Сохраняем конфигурацию стека командой “save”. Настройка завершена.
Подробную информация про iStack и пример настройки iStack можно также посмотреть на сайте Huawei.
Смена ip адресов на dad линках
MLAG-пару коммутаторов надо было переводить из песочницы в боевое окружение.
Надо было поменять vlan и ip адреса на Meth интерфейсах и в настройках dfs-group.
В документации описания такого процесса нет, но при этом известно, что коммутаторы через PL договариваются, в том числе и о адресах DAD линков.
Пожтому адреса решил не менять на живую, а сначала положить все порты на слейв ноде, тем самым изолировав ноды друг от друга, и только после этого менять адреса.
Распределение ролей коммутаторов в нормальном состоянии:
Последовательность действий коротко:
- Положить MLAG порты на sw22.
- Положить Meth порт c sw22.
- Зайти на sw22 через консоль и положить PL порты.
- На sw22 поменять адрес у meth0 интерфейса и в настройках dfs-group.
- Перенести sw21/meth0 в другой vlan, поднять порт meth0 и проверить, что можно зайти по ssh.
- Положить meth порт c sw21.
- Зайти на sw21 через консоль и поменять адрес у meth0 интерфейса и в настройках dfs-group.
- Поднять meth порт c sw21.
- Поднять MLAG порты на sw22.